A four-year observational investigation conducted from January 2020 to December 2023 in Lecce, Italy, revealed that extreme summer heat waves significantly amplified urban heat island intensity across multiple monitoring stations compared to non-heat wave conditions. Urban heat island intensity, evaluated as the air temperature difference between urban or suburban monitoring locations and an outlying rural reference station, was consistently elevated during periods of extreme heat. Across the full study duration, station averages during heat waves ranged between 0.74 degrees Celsius and 2.60 degrees Celsius, whereas non-heat wave summer averages fluctuated between 0.23 degrees Celsius and 1.79 degrees Celsius, demonstrating substantial thermal exacerbation within built environments.

    The study focused on Lecce, a Mediterranean municipality in southeastern Italy situated at 40 degrees 21 minutes 11 seconds North and 18 degrees 10 minutes 21 seconds East on the Salento peninsula. Lecce encompasses approximately 94,000 residents according to 2022 census figures and rests on a flat landscape ranging between 40 and 50 meters above sea level, located 13 kilometers from the Adriatic Sea and 25 kilometers from the Ionian Sea. The region exhibits a typical Mediterranean climate categorized as Csa under the Köppen-Geiger classification, marked by hot, dry summers and mild, wet winters. In summer, the Salento peninsula frequently experiences prolonged heat wave episodes driven by the sustained dominance of subtropical high-pressure weather systems.

    Lecce displays a radial urban configuration featuring an irregular historic centre built with narrow thoroughfares and compact modern districts constructed over recent decades. The historic centre is dominated by calcareous tufa masonry and thoroughfares paved in local stone, both exhibiting high thermal capacities and substantial heat conductivity. Across the wider urban fabric, primary factors governing urban heat islands include land cover alterations, urban sprawl, anthropogenic heat discharges from vehicular traffic, industrial functions, and building air conditioning systems, as well as a relative scarcity or absence of vegetated areas.

    To capture microclimatic variability, researchers evaluated thirty-minute air temperature measurements gathered by six automated weather monitoring stations operated by different public and research entities. Four stations were positioned within the urban fabric: ARPA, Ateneo, Rudiae, and Liceo Scientifico Tabacchi, abbreviated as LST. A fifth station, ISAC, operated in a suburban setting, while the rural baseline was established at Cerrate, situated approximately 12 kilometers outside Lecce’s centre near the Abbazia di Santa Maria di Cerrate. The Cerrate rural site is surrounded by agricultural fields and woodland, providing an unbuilt reference environment for computing urban heat island intensity as urban air temperature minus rural air temperature.

    Raw temperature observations logged at intervals between 10 and 30 minutes underwent despiking procedures to eliminate statistical outliers, alongside linear interpolation for data gaps spanning less than two hours. The overall percentage of verified air temperature records differed among the sites, registering 40 percent at Rudiae, 47 percent at ARPA, 68 percent at LST, 98 percent at ISAC, 98 percent at Cerrate, and 99 percent at Ateneo. Because data availability varied, seasons containing less than 70 percent of validated observations were excluded from seasonal calculations, and researchers noted that missing data, particularly from the ARPA station, influenced observed annual averages.

    Across the four-year observational span, seasonal averages exhibited distinct variations throughout the annual cycle. The summer seasonal average was the lowest at 0.71 degrees Celsius. Seasonal winter values across stations ranged from 0.92 degrees Celsius to 1.04 degrees Celsius, while summer values spanned between 0.47 degrees Celsius and 1.00 degrees Celsius, with heightened winter intensity linked to anthropogenic heat and reduced atmospheric turbulence and ventilation.

    Diurnal dynamics analyzed from hourly patterns displayed a recurring daily progression characterized by early morning peaks and afternoon troughs. At most monitoring stations, urban heat island intensity reached its diurnal peak between 06:00 and 07:00 local time, before declining sharply toward midday. Between 13:00 and 16:00 local time, values dropped to near zero or became slightly negative, with Rudiae recording minimum values down to -0.50 degrees Celsius at 15:00 local time. This negative anomaly identified an urban cold island effect fostered by light-coloured limestone materials that retain high thermal capacities within the historic core, before evening heat release from surfaces restored positive temperature anomalies overnight.

    Station microenvironments exerted a pronounced influence on recorded temperatures. The ARPA station diverged from the general diurnal pattern by maintaining an urban heat island intensity above 1.00 degrees Celsius during midday and reaching its peak intensity between 23:00 and 24:00 local time. ARPA consistently recorded the highest overall values, including a summer average of 1.97 degrees Celsius, driven by localized overheating near a sunlit wall and an adjacent asphalt parking lot. Conversely, LST and the suburban ISAC station recorded the lowest intensities, with LST averaging 0.37 degrees Celsius across seasons, largely reflecting the mitigating influence of extensive surrounding vegetation.

    The investigation classified heat wave occurrences using the Fischer and Schär criterion, defined as at least six consecutive days during which daily maximum air temperatures exceed the 90th percentile of baseline records compiled between 1991 and 2020 at the LST station. The long-term LST temperature series was validated through Pettitt, Buishand, and Khaliq and Ouarda homogeneity tests. Across the summer seasons of 2020 through 2023, eleven distinct heat waves occurred, exhibiting an average duration of approximately 10 days and an average daily maximum air temperature of 34.80 degrees Celsius.

    The annual distribution of summer extreme heat events varied throughout the four-year monitoring window. Two heat waves took place in 2020, while three events were logged in each subsequent year from 2021 to 2023. The 2022 summer recorded the greatest cumulative total of heat wave conditions at 36 days, whereas the 2021 summer recorded the highest mean daily maximum temperature during heat waves at 36.00 degrees Celsius. In every year examined, urban heat island intensities remained systematically higher during heat waves than during non-heat wave intervals across all urban and suburban monitoring locations.

    Thermal intensification during heat waves was particularly severe in densely built surroundings. The ARPA station registered the largest heat wave average intensity at 2.60 degrees Celsius, compared to 1.79 degrees Celsius during non-heat wave conditions, and recorded 75th percentile values exceeding 4.00 degrees Celsius during the 2020 heat waves. In contrast, the vegetated LST site recorded an average heat wave intensity of 0.74 degrees Celsius compared to 0.23 degrees Celsius during non-heat wave intervals, with its 75th percentile reaching 1.21 degrees Celsius during heat waves and dropping to 0.76 degrees Celsius in ordinary conditions.

    Statistical evaluation using the Student’s t-test following Shapiro-Wilk normality testing demonstrated statistically significant differences in urban heat island intensity between heat wave and non-heat wave periods for all stations with p-values spanning 0.0005 to 0.02, with the exception of the ARPA station. The mean thermal enhancement induced by heat waves was 0.73 degrees Celsius at the densely built ARPA site and 0.49 degrees Celsius at suburban ISAC, while difference values at remaining stations ranged between 0.51 degrees Celsius and 0.81 degrees Celsius. Researchers concluded that addressing heat wave amplification will require integrated approaches coupling conventional monitoring with numerical modeling and remote sensing to evaluate urban ventilation, thermal comfort, and energy demand.

    Subject of Research: Urban heat island intensity and heat wave dynamics in Lecce, Italy

    Article Title: Dynamics of urban heat island intensity in Lecce, Italy: seasonal, diurnal and heat wave influence

    Article References: Pappaccogli, G., Giangrande, F., Esposito, A., Donateo, A., Lionello, P., & Buccolieri, R. (2024). Dynamics of urban heat island intensity in Lecce, Italy: seasonal, diurnal and heat wave influence. Bulletin of Atmospheric Science and Technology, 5(1), Article 8. https://doi.org/10.1007/s42865-024-00072-z

    Image Credits: AI Generated

    DOI: 10.1007/s42865-024-00072-z

    Keywords: urban heat island, heat waves, Lecce, urban heat island intensity, air temperature, urban cold island, Mediterranean climate, Salento peninsula, weather stations, diurnal cycle, seasonal variation, anthropogenic heat, thermal comfort, ARPA station, Cerrate station, Student’s t-test, Fischer and Schär criterion

    Share.