Quickly
I bought an older apartment for myself, the wooden floors were in poor condition and I decided to remove them and now I want to make a new floor. Ceilings/floors are 220mm reinforced concrete hollow panel. In some places, there are metal pieces like the ones in the picture that run into the load-bearing wall.
Otherwise, in principle, they don’t bother me, but in two places where the floor panel is already about 1 cm higher than the other panels, these cleats give an additional 2 m of height, which is quite unnecessary if you need to start leveling the floor.
There are still such pieces in the apartment, but not on every panel, rather on fewer panels. They don’t seem to have any supporting role. The theory was that it was some kind of thing that was needed during assembly and no longer directly plays a role, but when it’s dry, you don’t dare to fly on it with a rail polish.
Maybe someone smarter can tell a) what exactly are they b) would it be okay to remove them?
Thank you!
https://www.reddit.com/gallery/1shn53t
Posted by MechaMamba

20 Comments
5g liinid, ära näpi, muidu MiB lendab kohale ja unustad projekti ära.
tundub nagu armatuur. hoone pikaealisema püsimise huvides üsna vajalik detail.
Lõika välja suva
Subscribing for updates
Hoiab nt seinu koos. On ta ees Sul?
Kui nad sind ei sega siis milleks üldse mõleda nende eemaldamisele?
Ilmselt põrandapaneelide ja seinte omavaheliseks sidumiseks. Ära näpi neid, need sinna ikka asjapärast pandud.
Üks ots läheb seina sisse ja teine ots on paneeli sees armatuuri külge keevitatud? Siis järelikult on vaja olnud kuidagi paneele seinte külge siduda ja on selline lahendus tehtud. Mitmes korrus…mis seal all on?
Ma lõikaks läbi, mida ta kooserdab seal põrandas ees…
Tunduvad nagu tõmbitsühendused, mida kasutati paneelide jäigastamiseks, eelkõige selleks, et välisseinad püsiksid paigal.
Kui juba lahti, siis kasutud – need peaks seinad ja põranda ehk siduma kokku.
Kui uut betooni valad, siis säti paika/puhasta roostest. Ja vala uus peale.
See on nurk. Nurk on vajalik neljakandilistes ruumides.
Piltidelt ei ole aru saada kas need on paneelide külge üldse ühendatud. Kui ei ole, siis lõika ära ja ilmselt tegu mingi ehitusaegse abinõuga kas valu või paneeli vms fikseerimisel.
Ehitajad unustasid, võid julgelt ära võtta. See hoidis maja koos, enne kui elanikud tapeedi seina said. Nüüd on mureta, tapeetide kiht on tugevam kui minigid mõttetud metalljupid.
potentsiaaliühtlustuskontuur. see on vajalik, et sa vannitoas kogemata pinge-alla ei satuks
Ühes suuremas vanas 5 korruselises hoones, kus põrandad kõik puidust, tegime põrandatalade tugevdamist tervele majale, vaid 5 betoontala kandmas puittalasid jooksid välisseina sisse, samad metallid olid vaid puittalade küljes mis omakorda olid lahtiselt kandvate betoontalade peal.
Ehk sisuliselt 5 korruselise maja sein seisab niisama püsti, vaid 5 betoontala korruse kohta hoiavad neid püsti kui on kuidagi seotud, läksid kõik need metallid eemaldamisele, midagi asemele ei pandud. Kui sul põrand õõnes paneel siis vaevalt midagi juhtub kui eemaldad, suurem probleem on sul nende pikkade avadega paneeli sees. Aga samas ei ole ma ka insener,
Ma ei saa aru kas see ots mis paneeli sees on, kas see on kinni või on see lahtiselt seal? Kui see on nii, et saad käega liigutada siis on savi, lõika minema see jama
Kuidas segab? Mis lahendus uueks põrandaks? Puit, betoon või kipsivalu?
See on viimne reliikvia!
Kuidas ette jäävad?
Kuna ennem oli laakide peal siis peaksid nagu nii tõstma hakkama. Ära otse tasandusvalu peale tee sest pärast su alumised naabrid tänavad sind, et kõik heli kohe neile kostub kõik. Tee nii, et põrand saaks “helikindel”. Paljud teevad korterites parandusi ja ei mõtle selle peale ja alumised kannatavad ja pärast sinu närvid kannatavad kui nad koguaeg uksel käivad.